Guia técnico da Karlead: especificações de produto, normas de plugue, conformidade de importação, transporte de baterias e planeamento de custos. Os códigos de normas são mantidos na forma internacional. Para confirmar modelo, MOQ e orçamento para o seu mercado, contacte sales@karlead.com.
Conhecimento do produto9 min readPublished 2026-11-13Pela equipa de compras da Karlead
Portable tire inflator specs: how to read PSI, inflation time and auto-stop
Almost every portable inflator in a catalogue claims the same maximum pressure. The difference shows up in how long it takes to get there, how many tyres it can finish on one charge, and whether the cut-off stops at the pressure printed on the display. Those are the three numbers worth putting into a purchase order.
A resposta curta
Maximum PSI is a ceiling, not a speed. Insist on inflation time quoted against a named reference tyre and a starting pressure.
Cylinder diameter, battery capacity and duty cycle together determine how many tyres a unit finishes before it needs a rest or a recharge.
Auto-stop accuracy is a test result, not a feature list item. Check it against a calibrated gauge on the incoming sample.
Compare carton quantity and gross weight as well as unit price: they change the landed cost per retail unit.
The four numbers on an inflator data sheet
Linha de especificações
What it tells you
What it does not tell you
Faixa de pressão
The working window of the pump and the gauge units offered
How fast it reaches the target, or how accurately it stops
Tempo de inflagem
Time to inflate a named reference tyre under stated conditions
What happens on a larger tyre, or after the unit is warm
Diâmetro do cilindro
A proxy for air volume per stroke
Real airflow, which also depends on motor speed and gearing
Capacidade da bateria or supply
Whether the unit is cordless, DC12V, or part of a multi-function unit
How many tyres remain after the first one
A data sheet with only a pressure range and a photo is a consumer listing, not a sourcing specification.
Tempo de inflagem is meaningless without the reference tyre
Our AC-001 data sheet states 9 min 30 s for a 195/65/R15 car tyre, with 1.5 tyres per charge and a 17 mm cylinder. AC-6188 lists 5 min for the same reference tyre with a 22 mm cylinder. Those two lines are comparable because the reference tyre is named. A claim of "fast inflation" with no reference tyre is not comparable with anything.
Modelo
Faixa de pressão
Cylinder
Tempo de inflagem (195/65/R15)
Tyres per charge
Power
AC-001
3-150 PSI / 0.2-10.3 BAR
17 mm
9 min 30 s
1.5
7.4 V lithium, 2000 mAh x 2
AC-0013
3-150 PSI / 0.2-10.3 BAR
17 mm
9 min 30 s
1.5
7.4 V lithium, 2000 mAh x 2
AC-6188
3-150 PSI / 0.2-10.3 BAR
22 mm
5 min
Listed on the model sheet
DC12V in-car / 11.1 V battery version
AC-2001
3-150 PSI / 0.2-10.3 BAR
19 mm
8 min
3
14.8 V jump starter, 2000 mAh x 4
Catalogue values from the model data sheets. Always confirm the current revision with the quotation, because packaging and battery versions change.
Auto-stop accuracy, gauge units and the display
Our AC-001 and AC-0013 sheets list PSI, BAR, KPA and Kg/cm² as selectable units. Confirm which unit is the default at power-on for your market, and whether the manual explains the others.
Test the cut-off against a calibrated gauge at three targets: low, mid and near the top of the range. Record the deviation, not just a pass or fail.
Check what happens when the target is reached while the hose is still attached, and whether the unit resumes automatically if pressure falls.
Ask whether the pressure sensor is a separate component with its own calibration record, and how a drift is corrected in a production run.
Lithium, DC12V or a jump-starter combination
Power architecture
Best fit
Buyer check
7.4 V lithium, cordless
Retail, e-commerce, emergency kits, bicycle and motorcycle use
Real tyres per charge, charging connector, lithium transport documents
DC12V in-car
Workshop, fleet, drivers who keep the engine running
Cable length, fuse, current draw, behaviour at low battery voltage
Jump starter with built-in compressor
Premium roadside bundles and multi-function displays
Compressor tested separately from cranking; heat after repeated use
The best-selling configuration in a short-form video is often the cordless one; the best-selling configuration in a workshop catalogue is often the DC12V one. Pick for the channel.
Noise, heat and duty cycle: the test a data sheet omits
A small compressor gets hot. What matters commercially is whether the unit finishes a second tyre without a thermal cut-out, and what the user hears while it does. Neither appears in a four-line parameter sheet, so both belong in your sample protocol.
Inflate the reference tyre from the stated starting pressure and log the time, the final pressure and the housing temperature.
Immediately repeat on a second tyre and log whether a thermal cut-out interrupts the run.
Measure noise at a fixed distance with the unit on a hard surface and on a carpet, because retail complaints often come from the hard-surface case.
Cycle the unit through the agreed number of charge and discharge rounds, then repeat the first test and compare the times.
Carton maths that changes the landed cost
Modelo
Peso líquido
Colour box
Pcs per carton
Tamanho da caixa
Peso do cartão
AC-001
0.41 kg
90 x 72 x 148 mm
24
38 x 23 x 31.5 cm
13 kg
AC-0013
0.395 kg
93 x 74 x 157 mm
24
30.7 x 29.5 x 35.3 cm
13.5 kg
Two units with nearly identical performance figures pack differently. Model the freight on the carton, not on the unit.
What to put in the RFQ
The exact pressure range and available gauge units, with the default unit for your market.
Tempo de inflagem and tyres per charge tied to a named reference tyre and starting pressure.
Cylinder diameter, motor type, hose length, nozzle set and included adapters.
Auto-stop tolerance at three target pressures, measured against a calibrated gauge.
Bateria version, charging connector, carton quantity and carton dimensions.
Manual language, artwork version and the test record that ships with the order.
If you plan to advertise a "150 PSI" inflator, confirm that the claimed maximum is a working range with an auto-stop target, not an unreachable ceiling. Retailers ask for the same evidence you should be asking for.
Perguntas frequentes
Quais são as principais especificações do este modelo?
A ficha técnica do este modelo é apresentada na tabela de parâmetros desta página. Confirme plugue, voltagem, capacidade e embalagem por escrito antes do pedido.
O este modelo aceita logótipo e embalagem personalizados?
Sim. Impressão do logótipo, cor da carcaça, arte da caixa, idioma do manual e padrão de plugue podem ser especificados em moldes existentes, sujeitos a MOQ por configuração.
Qual é o MOQ e o prazo de entrega do este modelo?
O MOQ é cotado por modelo e varia com a cor, o plugue e a embalagem. Envie a quantidade pretendida e o mercado de destino para receber preço unitário, MOQ e prazo por escrito.
Posso receber amostras do este modelo antes do pedido?
Sim. Amostras de modelos listados podem ser organizadas mediante solicitação; amostras de pré-produção são submetidas à sua aprovação escrita antes da produção em massa.
Que opções de plugue e voltagem existem para o este modelo?
O padrão de plugue e a voltagem são definidos por mercado (UK, US, AU, EU e Brasil NBR 14136, entre outros). Indique o país de destino na consulta para fixarmos a configuração correta.
Como solicito um orçamento para o este modelo?
Envie um e-mail para sales@karlead.com com o modelo, o mercado de destino, o padrão de plugue e a quantidade. Respondemos normalmente em um dia útil com preço, MOQ, prazo e dados de embalagem.
Que normas de plugue e voltagem estão disponíveis?
Os padrões UK, US, AU, EU e Brasil (NBR 14136) podem ser especificados por mercado, bem como 127 V / 220 V. Indique o país de destino na consulta para fixarmos a configuração antes da produção.
Como são definidos MOQ e embalagem de exportação?
O MOQ e as unidades por caixa são indicados por modelo na ficha técnica. Caixas de exportação ou embalagem de varejo personalizada podem ser combinadas por escrito, com registo de lote em cada envio.